Chlorine Decay Calculator

Chlorine Decay Calculator

Will your residual hold to the far end of the system? Enter your starting residual and decay constant to project the residual at any water age — and find out how long until it drops to your target.





Projected Residual
Item Value

How the calculation works

Formulas (first-order decay)
C(t) = C₀ · e−k·t — C in mg/L, k in 1/hr, t in hr
Half-life t½ = ln(2) / k
Time to target = ln(C₀ / Ctarget) / k  (only when 0 < Ctarget < C₀)

Notes & limitations

First-order chlorine decay is the standard distribution-system residual model (AWWA M20; distribution water quality literature). The decay constant k is system-specific — there is no universal textbook value.
  • Derive k from your own field data: measure residuals at two points with known water ages, then k = ln(C₁/C₂) / (t₂ − t₁). Re-derive seasonally — k rises in warm water.
  • First-order fits bulk decay well but ignores wall demand hotspots (unlined cast iron, dead ends). Field-verify before changing doses.
  • This projects disinfectant residual only. CT compliance at the plant is a separate calculation — see the CT calculator.

← All water treatment calculators · Related: Chlorine Dose Calculator