Composite Sampler Pacing Calculator

Composite Sampler Pacing Calculator

Program a flow-paced composite sampler: enter the bottle size, the number of aliquots, and the flow to be sampled, and get the aliquot volume and pacing interval.





Flow-Paced Composite Setup
Item Value

How the calculation works

Flow-paced composite setup
Aliquot volume (mL) = bottle volume (L) × 1,000 ÷ number of aliquots
Flow per aliquot (gal) = total flow (gal) ÷ number of aliquots
Pulses per aliquot = flow per aliquot (gal) ÷ pulse volume (gal/pulse)

Notes & limitations

Flow-paced (flow-proportional) composites are the standard for NPDES wastewater compliance sampling (see 40 CFR 122.21 and your permit’s sampling section): each aliquot represents an equal volume of flow, so the composite reflects the true flow-weighted concentration.
  • Keep individual aliquots at 100 mL or more when practical so the lab has enough volume for every analysis plus QC.
  • Refrigerate the composite at ≤ 6°C during collection; observe the holding time for each parameter in 40 CFR 136.
  • Time-paced composites are acceptable only where the permit allows them — they bias toward high-flow periods in variable flows.
  • Verify the sampler intake velocity and purge settings per the manufacturer’s manual and your sampling plan.

← All water treatment calculators · Related: Lead/Copper 90th Percentile Calculator