Darcy-Weisbach Head Loss Calculator

Darcy-Weisbach Head Loss Calculator

Friction loss is the backbone of every pipe sizing and pump head calculation. Enter flow, pipe size, length, and roughness to get Darcy-Weisbach head loss with the friction factor solved for you.









Friction Head Loss
Item Value

How the calculation works

Darcy-Weisbach equation
hf = f · (L / D) · (V² / 2g)
V = Q / A,  A = πD² / 4,  g = 32.2 ft/s²
Reynolds number Re = V · D / ν
Haaland approximation (turbulent flow, explicit form of Colebrook-White):
1/√f = −1.8 · log10[ (ε/D / 3.7)1.11 + 6.9/Re ]
Laminar flow (Re < 2,300): f = 64 / Re
Dynamic viscosity from the Vogel-type water correlation μ = 2.414×10−5 · 10247.8/(TK−140) Pa·s; ν = μ/ρ
psi = ft of head × 0.4333
Pipe material Typical roughness ε (mm)
PVC / HDPE 0.0015
Commercial steel 0.045
Cement-lined ductile iron 0.10–0.15
Cast iron, unlined 0.26
Concrete 0.3–3.0

Notes & limitations

The Darcy-Weisbach equation with the Colebrook-White friction factor (via the Haaland explicit approximation, 1983) is the standard for pressurized pipe flow — see any fluid mechanics text (e.g., Munson, Young & Okiishi) or Crane Technical Paper No. 410. Roughness values are typical new-pipe values; tuberculation and scaling raise ε with age.
  • For full pipe flow only. Partially-full gravity sewers use Manning’s equation instead.
  • Aged pipe can have several times the new-pipe roughness — field-verify with pressure-drop tests on old mains.
  • Add minor (fitting) losses separately; this page covers friction loss only.
  • The Haaland approximation is valid for turbulent flow (Re > 4,000); laminar flow uses f = 64/Re automatically here.