Equalization Basin Volume Calculator

Equalization Basin Volume Calculator

Dampen diurnal flow swings before downstream treatment. Enter your average flow, peak factor, and how long flows run above average to size the basin.





Equalization Volume
Item Value

How the calculation works

Formulas (constant-outflow method)
Peak flow = peak ratio × average flow
Surplus rate during peak block = (peak ratio − 1) × average flow
Storage (MG) = surplus rate (MGD) × peak hours ÷ 24
Storage (% of daily flow) = storage (MG) ÷ average daily flow (MG) × 100
Off-peak flow = (24 × average − peak hours × peak flow) ÷ (24 − peak hours)
Detention at average flow (hr) = storage (gal) ÷ average flow (gph)
Plant size Typical peak / average ratio
Small (< 1 MGD) 2.5 – 3.0
Medium (1 – 10 MGD) 2.0 – 2.5
Large (> 10 MGD) 1.5 – 2.0

Notes & limitations

This is the simplified constant-outflow (cumulative surplus) method described in Metcalf & Eddy. Final design should use the full diurnal hydrograph with a mass-curve analysis, and include freeboard plus a mixing/aeration system to keep solids suspended.
  • The peak-hours × peak-ratio combination must balance over 24 hours — the tool rejects combinations where the implied off-peak flow goes negative.
  • Equalization ahead of biological treatment also dampens load swings (BOD), not just flow — size for the governing case.
  • Provide mixing (typically 0.5–1.0 hp per 1,000 ft3 or diffused air) so the basin does not turn septic.